    质量与环境 > 可靠性实验室
    可靠性实验室


    Ø 意昂体育股份有限公司集团实验室拥有国内一流的功率分立器件及特色IC产品的可靠性及失效分析实验设施,设备,实验室项目参考JEDEC相关标准。
    Ø 主要有可靠性实验和失效分析实验两块主要业务。实验室在2025年1月通过CNAS的认证,CNAS22280。



    实验室对外承接可靠性试验项目:

    Ø 温湿度试验(HTSL/PCT/UHAST/THT/TC/TS)

    Ø 老化试验(HTRB/HTGB/H3TRB/IOL/HAST)

    Ø 封装体完整性测试(RSH/SD/MSL)

    Ø 产品特性参数测试(ESD/Surge/Thermal Resistance)



    具体测试项目及条件:

    NO.

    Stress

    ABV

    Reference

    Test Condition

    Capability

    1

    Pre-conditioning

    PC

    JESD22A-113

    only for SMD product H3TRB, HAST, UHAST, AC, IOL,TC and RSH test items.


    2

    High Temperature Reverse Bias

    HTRB

    JESD22A-108

    TJ:MAX, 100%VR;Interim readout @168HR,@500HR, final @1000HR;

    Temp: RT~200℃;

    Voltage:0~2000V;

    3

    High Temperature Gate Bias

    HTGB

    JESD22A-108

    TJ:MAX, 100%VGS;Interim readout @168HR,@500HR, final @1000HR;

    Temp: RT~200℃;Voltage:0~100V;

    4

    High Humidity High Temp. Reverse Bias

    H3TRB

    JESD22A-101

    85°C, 85%RH, 80%VR;Interim readout @168HR,@500HR, final @1000HR;

    Temp&Humidity: 85℃,85%;Voltage:0~1000V;

    5

    Temperature Cycling

    TCT

    JESD22A-104

    -55°C to 150°C, dwell time >=10min;Interim readout @168 cycles,@500 cycles, final @1000 cycles;

    Temp: -70℃~200℃;
    Temp ramp up to 18℃/min

    6

    Autoclave

    AC

    JESD22A-102

    121°C, 100%RH, 15psig;Final readout @96HR


    7

    Intermittent Operational Life

    IOL

    MIL-STD-750-1037

    Ta=25°C,2on 2off,∆TJ ≥ 100°C;Interim readout @2520 cycles,@7500 cycles, final @15000 cycles;

    Current: 0~16A
    Voltage: 0~20V

    8

    Resistance to Solder Heat

    RSH

    JEDEC JESD22-A-
    111 (SMD), or B-106 (PTH)

    260°C/10S


    9

    Solderability

    SD

    J-STD-002

    245°C/5S S≥95%


    10

    Electrostatic Discharge Testing-Human Body Model

    ESD-HBM

    AEC-Q101-001

    R=1500Ω,C=100PF

    Voltage: 0~8KV

    11

    Destructive Physical Analysis 

    DPA 

    AEC-Q101-004 

    H3TRB or HAST, and TCT


    12

    Forward Surge Test

    FS 

    MIL-STD-750-4066 

    T:8.3MS

    Current: 0~1KA

    13

    Thermal Shock

    TS

    JESD22A106B

    -65°C ~ 150°C

    Temp: -70℃~200℃

    或按照顾客特定要求,如Double AECQ101等.


    失效分析实验室:

    Ø 开封

    Ø 取晶粒

    Ø 红墨水试验

    Ø X射线透视

    Ø 探针测试

    Ø 高倍显微镜拍照

    Ø 背面研磨

    Ø 横截面切片


    联系电话:17751114968

    邮箱:Labservice@hbfqydt.com

    地址:苏州市虎丘区通安镇真北路100号